 Trans Instruments has
specially designed the KoiMedic tester to measure the delicate salt concentration in
the pond. Two models of your choice measuring in percentage(%) or parts-per-thousand
(ppt). The testers are accurate and easy to use. All you need to do is
turn it on and dip into the pond water.
The Koi Medic provides accurate
results and is very easy to use, simply turn on and hold in the pond. Within a
couple seconds the LCD displays the salt concentration measured in percentage.
Measures accurately from .01% to 1%.
Salt concentrations between 0.3% and
0.5%(3 to 5ppt) will upset the osmotic balance of some parasites i.e. the
parasites’ cells will dehydrate. Salt concentration of 0.3% are
effective at detoxifying nitrite and concentration of 0.25% or higher has been used
to control string algae. Nevertheless, salt can cause pond plant damage as the
concentration increases. Floating plants (water hyacinth, water lettuce, etc.)
are affected at lower concentrations than most bog plants.
| Specifications |
| Units of measurement |
% |
| Range |
0.00 - 1.00% |
| Resolution |
0.01% |
| Accuracy |
±0.03% |
| Battery Type |
4 x
1.5V Button Cell (Alkaline A76 or equivalent) |
| Battery Life |
Approximately 150 hours
(Continuous Use) |
| Automatic Shut-off |
Approximately 15
minutes |
| Temperature
Compensation |
Automatic 0 - 50 degrees Centigrade |
| Operating Temperature |
0 - 50 degrees Centigrade |
| Size (L x W x H) |
170mm x 32mm x 15mm |
| Weight |
Approximately 70 g |
|